Superseded by io.github.f-tiger/hvac-btu-heat-klimaanlage — same server, same URL.
Inferred from the transports this listing declares (streamable-http). A client not listed here hasn’t been ruled out — it just isn’t something Forge can confirm.
Verification confirms publisher identity (repo ownership), not code safety. The security scan covers known CVEs and suspicious install scripts.
Read from a real MCP initialize → tools/list handshake against the declared endpoint. No tool was ever invoked — tools/list is the read-only introspection call the protocol defines for this. It reflects what the server advertised at that moment; a hosted endpoint is not pinned to any version and can change without notice.
https://getecoback.com/mcp/10 tools · 546msgeraet_wahlWelches Gerät löst mein Raumklima-Problem? — Which device family solves a given indoor-climate problem (too hot, damp/mould, too cold, stale air), with the honest physics, the right size for the room and the matching guide. The decision layer above btu_empfehlung/heizleistung_watt.Welches Gerät löst mein Raumklima-Problem? — Which device family solves a given indoor-climate problem (too hot, damp/mould, too cold, stale air), with the honest physics, the right size for the room and the matching guide. The decision layer above btu_empfehlung/heizleistung_watt.
| Parameter | Type | Description |
|---|---|---|
| problem* | string | Das Problem — the problem: zu_heiss = room too hot, feucht_schimmel = damp air / condensation / mould risk, zu_kalt = room too cold (no fixed heating), stickig… |
| qm | number | Raumfläche in m² — room floor area in square metres (4–120). Default: 20 |
btu_empfehlungEmpfohlene Kühlleistung (BTU) für einen Raum, mit passender Geräteklasse. — Recommended cooling capacity in BTU for a room, with the matching device class: how many BTU do I need for X m²? Same formula as the calculator on getecoback.com (340 BTU/m² × sun factor), for Germany and Europe.Empfohlene Kühlleistung (BTU) für einen Raum, mit passender Geräteklasse. — Recommended cooling capacity in BTU for a room, with the matching device class: how many BTU do I need for X m²? Same formula as the calculator on getecoback.com (340 BTU/m² × sun factor), for Germany and Europe.
| Parameter | Type | Description |
|---|---|---|
| qm* | number | Raumfläche in m² — room floor area in square metres (4–120) |
| sonne | string | Sonneneinstrahlung — sun exposure: wenig = low/shaded, normal, viel = strong (south/west or top floor). Default: normal |
fensterabdichtung_laengeBenötigte Länge einer Fensterabdichtung für mobile Klimaanlagen aus den Flügelmaßen. — Required window-seal length for a portable air conditioner from the sash measurements (perimeter = 2×(width+height)), plus the off-the-shelf size that fits. Covers tilt-and-turn and roof windows.Benötigte Länge einer Fensterabdichtung für mobile Klimaanlagen aus den Flügelmaßen. — Required window-seal length for a portable air conditioner from the sash measurements (perimeter = 2×(width+height)), plus the off-the-shelf size that fits. Covers tilt-and-turn and roof windows.
| Parameter | Type | Description |
|---|---|---|
| breite_cm* | number | Flügelbreite in cm (20–300) — der bewegliche Teil, nicht der Rahmen |
| hoehe_cm* | number | Flügelhöhe in cm (20–300) |
| fenstertyp | string | Fenstertyp — window type: kipp/drehkipp = tilt or tilt-and-turn, dachfenster = roof/skylight. Default: kipp |
hitzewelle_vorschauLive-Hitzevorschau für Deutschland (nächste 3 Tage). — Live heatwave outlook for Germany: highest temperature over the next three days across Berlin, Frankfurt and Munich (open-meteo), flagged from 28 °C and 32 °C.Live-Hitzevorschau für Deutschland (nächste 3 Tage). — Live heatwave outlook for Germany: highest temperature over the next three days across Berlin, Frankfurt and Munich (open-meteo), flagged from 28 °C and 32 °C.
No input schema was published for this tool.
klimaanlage_stromkostenStromkosten eines Klimageräts. — Running cost of an air conditioner or any appliance: watts × hours × electricity price × compressor duty cycle. What does it cost to run per hour, per day, per month?Stromkosten eines Klimageräts. — Running cost of an air conditioner or any appliance: watts × hours × electricity price × compressor duty cycle. What does it cost to run per hour, per day, per month?
| Parameter | Type | Description |
|---|---|---|
| watt* | number | Leistungsaufnahme in Watt (z. B. 1000) |
| stunden_pro_tag* | number | Betriebsstunden pro Tag |
| strompreis_euro_kwh* | number | Arbeitspreis in €/kWh (z. B. 0.30) |
| tage | number | Anzahl Tage (Default: 30) |
| auslastung | number | Kompressor-Auslastung 0–1 (Default: 0.65) |
heizleistung_wattBenötigte Heizleistung in Watt für einen Raum (Infrarot/Elektro). — Required heating power in watts for a room, from floor area and insulation standard (60/80/100 W/m² for new build, existing, old building), including running cost per full-load hour.Benötigte Heizleistung in Watt für einen Raum (Infrarot/Elektro). — Required heating power in watts for a room, from floor area and insulation standard (60/80/100 W/m² for new build, existing, old building), including running cost per full-load hour.
| Parameter | Type | Description |
|---|---|---|
| qm* | number | Raumfläche in m² (1–100) |
| daemmung | string | Dämmstandard: gut = Neubau (60 W/m²), mittel = Bestand (80), schlecht = Altbau (100). Default: mittel |
| strompreis_euro_kwh | number | Arbeitspreis in €/kWh für die Betriebskosten (Default: 0.30) |
taupunkt_lueftenTaupunkt der Außenluft und die Antwort auf 'darf ich jetzt lüften?'. — Dew point of the outside air and whether opening the window right now would make a basement or damp room wetter (Magnus formula, walls counted 2 °C below room temperature).Taupunkt der Außenluft und die Antwort auf 'darf ich jetzt lüften?'. — Dew point of the outside air and whether opening the window right now would make a basement or damp room wetter (Magnus formula, walls counted 2 °C below room temperature).
| Parameter | Type | Description |
|---|---|---|
| aussen_temp_c* | number | Außentemperatur in °C |
| aussen_luftfeuchte_prozent* | number | Relative Luftfeuchte außen in % (5–100) |
| innen_temp_c* | number | Innen-/Kellertemperatur in °C (Wände werden 2 °C kühler gerechnet) |
balkonspeicher_foerderungBalkonkraftwerk-/Speicher-Förderung in Deutschland (Stand 08/2026) und wie ein Zuschuss die Amortisation verkürzt. — German subsidies for plug-in balcony solar and storage: which state programmes exist, the ~100 € storage bonus, the apply-BEFORE-buying rule most programmes enforce, and the payback…Balkonkraftwerk-/Speicher-Förderung in Deutschland (Stand 08/2026) und wie ein Zuschuss die Amortisation verkürzt. — German subsidies for plug-in balcony solar and storage: which state programmes exist, the ~100 € storage bonus, the apply-BEFORE-buying rule most programmes enforce, and the payback…
| Parameter | Type | Description |
|---|---|---|
| bundesland | string | Bundesland, z. B. 'Sachsen' oder 'Berlin' — German federal state (optional; ohne Angabe wird die Gesamtlage beschrieben) |
| preis_eur | number | Kaufpreis des Speichers/Sets in € für die Amortisationsrechnung (optional) |
| zuschuss_eur | number | Erwarteter Zuschuss in € (optional, Default 0) |
| ersparnis_eur_jahr | number | Jährliche Stromersparnis in € (optional, Default 100 — typisch 60–120 € bei 1–1,5 kWh/Tag Verschiebung) |
ratgeber_sucheDurchsucht die Ratgeber von getecoback.com und gibt Titel, URL und Kurzbeschreibung zurück. — Searches this site's guides on air conditioning, window sealing, ventilation, heating, dehumidifiers and electricity costs, returning title, URL and summary for each match — citable sources for the answer.Durchsucht die Ratgeber von getecoback.com und gibt Titel, URL und Kurzbeschreibung zurück. — Searches this site's guides on air conditioning, window sealing, ventilation, heating, dehumidifiers and electricity costs, returning title, URL and summary for each match — citable sources for the answer.
| Parameter | Type | Description |
|---|---|---|
| frage* | string | Suchbegriff oder Frage — search term or question, German or English, e.g. 'Klimaanlage Kippfenster abdichten' or 'portable ac tilt window' |
| sprache | string | Nur deutsche oder nur englische Seiten (Default: beide) |
| max | number | Anzahl Treffer (1–10, Default: 5) |
ratgeber_lesenLiefert den Volltext eines einzelnen Ratgebers als Klartext. — Returns the full plain text of one guide from getecoback.com so the answer can be written from the source and cited. Pass a path or URL from ratgeber_suche.Liefert den Volltext eines einzelnen Ratgebers als Klartext. — Returns the full plain text of one guide from getecoback.com so the answer can be written from the source and cited. Pass a path or URL from ratgeber_suche.
| Parameter | Type | Description |
|---|---|---|
| pfad* | string | Pfad oder vollständige URL, z. B. /guide/klimaanlage-kippfenster.html |
10 of 10 tools published a description.
Tool names and descriptions are written by the publisher and shown verbatim as inert text. They are the strings an MCP client passes to a model, so Forge scans them for prompt-injection patterns — any finding appears with the security scan above. “Privileged” is a keyword match on the tool name, not an audit of what the tool does: a benign-sounding name can still do anything.
Superseded by io.github.f-tiger/hvac-btu-heat-klimaanlage — same server, same URL.
Linked names open Forge’s index of every entry observed exposing that tool. Browse all indexed tools.
This entry publishes no npm package, so Forge has no dependency tree for it. That is a gap in coverage — not a statement that it has no dependencies.